TOP
0
0
即日起~6/30,暑期閱讀書展,好書7折起
System Theory And Practical Applications Of Biomedical Signals
滿額折

System Theory And Practical Applications Of Biomedical Signals

商品資訊

定價
:NT$ 9673 元
優惠價
908706
若需訂購本書,請電洽客服 02-25006600[分機130、131]。
相關商品
商品簡介
作者簡介
目次

商品簡介

System theory is becoming increasingly important to medical applications. Yet, biomedical and digital signal processing researchers rarely have expertise in practical medical applications, and medical instrumentation designers usually are unfamiliar with system theory. System Theory and Practical Applications for Biomedical Signals bridges those gaps in a practical manner, showing how various aspects of system theory are put into practice by industry.
The chapters are intentionally organized in groups of two chapters, with the first chapter describing a system theory technology, and the second chapter describing an industrial application of this technology. Each theory chapter contains a general overview of a system theory technology, which is intended as background material for the application chapter. Each application chapter contains a history of a highlighted medical instrument, summary of appropriate physiology, discussion of the problem of interest and previous empirical solutions, and review of a solution that utilizes the theory in the previous chapter.
Biomedical and DSP academic researchers pursuing grants and industry funding will find its real-world approach extremely valuable. Its in-depth discussion of the theoretical issues will clarify for medical instrumentation managers how system theory can compensate for less-than-ideal sensors. With application MATLAB? exercises and suggestions for system theory course work included, the text also fills the need for detailed information for students or practicing engineers interested in instrument design. An Instructor Support FTP site is available from the Wiley editorial department: ftp://ftp.ieee.org/uploads/press/baura

作者簡介

GAIL D. BAURA received a BSEE from Loyola Marymount University in 1984 and an MSEE and MSBME from Drexel University in 1987. She received a PhD in Bioengineering from the University of Washington in 1993. Between these degrees, Dr. Baura worked as a loop transmission systems engineer at AT&T Bell Laboratories. Since graduation, she has served in a variety of research positions at IVAC Corporation, Cardiotronics Systems, Alaris Medical Systems, and VitalWave Corporation. Dr. Baura is currently Vice President of Research at CardioDynamics. Her research interests are the application of system theory to patient monitoring and insulin metabolism.

目次

Preface.

Nomenclature.

I FILTERS.

1 System Theory and Frequency-Selective Filters.

2 Low Flow Rate Occlusion Detection Using Resistance Monitoring.

3 Adaptive Filters.

4 Improved Pulse Oximetry.

5 Time-Frequency and Time-Scale Analysis.

6 Improved Impedance Cardiography.

II MODELS FOR REAL TIME PROCESSING.

7 Linear System Identification.

8 External Defibrillation Waveform Optimization.

9 Nonlinear System Identification.

10 Improved Screening for Cervical Cancer.

11 Fuzzy Models.

12 Continuous Noninvasive Blood Pressure Monitoring: Proof of Concept.

III COMPARTMENTAL MODELS.

13 The Linear Compartmental Model.

14 Pharmacologic Stress Testing Using Closed-Loop Drug Delivery.

15 The Nonlinear Compartmental Model.

16 The Role of Nonlinear Compartmental Models in Development of Antiobesity Drugs.

IV SYSTEM THEORY IMPLEMENTATION.

17 Algorithm Implementation.

18 The Need for More System Theory in Low-Cost Medical Applications.

Glossary.

Index.

您曾經瀏覽過的商品

購物須知

外文書商品之書封,為出版社提供之樣本。實際出貨商品,以出版社所提供之現有版本為主。部份書籍,因出版社供應狀況特殊,匯率將依實際狀況做調整。

無庫存之商品,在您完成訂單程序之後,將以空運的方式為你下單調貨。為了縮短等待的時間,建議您將外文書與其他商品分開下單,以獲得最快的取貨速度,平均調貨時間為1~2個月。

為了保護您的權益,「三民網路書店」提供會員七日商品鑑賞期(收到商品為起始日)。

若要辦理退貨,請在商品鑑賞期內寄回,且商品必須是全新狀態與完整包裝(商品、附件、發票、隨貨贈品等)否則恕不接受退貨。

優惠價:90 8706
若需訂購本書,請電洽客服 02-25006600[分機130、131]。

暢銷榜

客服中心

收藏

會員專區